Load Shackles
Scotload’s innovative load shackles are ideal for lifting and weighing applications where there is limited headroom.

We provide load shackles that are manufactured from GN or Van Beest shackles as standard, but other manufacturers are available on request. We provide a fully stainless steel construction (excluding bow) up to 85 tonnes as standard, and fully stainless steel construction for 120 tonnes and above upon request.
We have a large range of shackles available in stock up to 1000 tonnes for purchase or hire, and ready for immediate dispatch. Larger capacities are available on request and all of our load shackles are supplied with full calibration and proof load certificates.
Download load shackles data sheet.
Features and benefits of load shackles:
- Internally gauged, fully welded and hermetically sealed
- Robust construction
- Internal antenna for added protection
- In stock available for immediate dispatch
- Stainless steel centralising load bobbin supplied as standard
- Robust stainless steel protection cage for electronics
Cabled load shackle typical specification:
| mV/V output | mA output | |
| Rated load | As required | As required |
| Proof load | 150% of rate load | 150% of rate load |
| Non-linearity | < ± 1% of full scale | < ± 1% of full scale |
| Non-repeatability | < ± 0.1% of full scale | < ± 0.1% of full scale |
| Zero balance | < ±0.1% of full scale | < ±0.1% of full scale |
| Environmental protection | IP67 / IP68 | IP67 / IP68 |
| Safety factor | 3x | 3x |
| Operating temperature | -25oC to +70oC | -25oC to +70oC |
| Storage temperature | -30oC to +80oC | -30oC to +80oC |
| Cable connection | Gland or connector | Gland or connector |
| Cable length | 5m as standard | 5m as standard |
| Output signal | mV/V | 4-20mA |
| Electrical connection | 4 core | 2 or 3 wire |
| Recommended excitation voltage | 10V | N/A |
| Maximum excitation voltage | 15V | N/A |
| Recommended supply voltage | N/A | 24V |
| Maximum supply voltage | N/A | 30V |
| Bridge resistance | 700 Ohm | N/A |
Wireless load shackle typical specification:
| Wireless output | |
| Rated load | As required |
| Proof load | 150% of rate load |
| Non-linearity | < ± 1% of full scale |
| Non-repeatability | < ± 0.1% of full scale |
| Zero balance | < ±0.1% of full scale |
| Environmental protection | IP67 / IP68 |
| Safety factor | 3x |
| Operating temperature | -25oC to +70oC |
| Storage temperature | -30oC to +80oC |
| Output signal | Wireless |
| Data logging | On load cell |
| Battery type | 4 x AA |
| Active battery type | Up to 350 hours |
| Standby battery type | Up to 1700 hours |
| Telemetry frequency | 2.4Ghz ISM |
| System range | Up to 350m |
| Sampling rate | 10Hz (500Hz max) |
Diagrams:
Cabled load shackle typical dimensions:
| Product code | Load rating (tonnes) | Weight B (kg) | Weight D (kg) | A mm | B mm | C mm | D mm | E mm | F mm | G mm (B) | G mm (D) | H mm (B) | H mm (D) | I mm (B) | J mm | K mm | L mm | M mm | |
| 8.5Te | 10269 | 8.5 | 2.6 | 2.5 | 43 | 93 | 59 | 28 | 44 | 25 | 95 | 85 | 164 | 154 | 68 | 159 | 110 | 50 | 54 |
| 12Te | 10270 | 12 | 4.9 | 4.5 | 51 | 115 | 72 | 35 | 50 | 32 | 115 | 94 | 201 | 180 | 83 | 209 | 119 | 50 | 55 |
| 17Te | 10271 | 17 | 8.2 | 7.6 | 60 | 136 | 88 | 42 | 63 | 38 | 146 | 127 | 249 | 230 | 99 | 242 | 131 | 50 | 57 |
| 25Te | 10272 | 25 | 14.2 | 12.9 | 74 | 164 | 103 | 50 | 88 | 45 | 178 | 149 | 300 | 271 | 126 | 276 | 136 | 60 | 57 |
| 35Te | 10273 | 35 | 19.9 | 17.4 | 83 | 183 | 111 | 57 | 88 | 50 | 197 | 171 | 331 | 305 | 138 | 297 | 160 | 75 | 57 |
| 55Te | 10274 | 55 | 39.6 | 35.3 | 105 | 235 | 145 | 70 | 114 | 65 | 260 | 203 | 433 | 376 | 180 | 347 | 180 | 88 | 55 |
| 85Te | 10275 | 85 | 62 | 53 | 127 | 273 | 162 | 83 | 125 | 75 | 329 | 339 | 527 | 427 | 190 | 391 | 205 | 100 | 55 |
| 120Te | 10276 | 120 | 110 | N/A | 150 | 328 | 200 | 95 | 152 | 89 | 380 | N/A | 617 | N/A | 238 | 440 | N/A | N/A | 50 |
| 150Te | 10277 | 150 | 160 | N/A | 170 | 374 | 230 | 108 | 165 | 102 | 400 | N/A | 671 | N/A | 275 | 493 | N/A | N/A | 50 |
| 200Te | 10278 | 200 | 235 | N/A | 180 | 420 | 260 | 140 | 190 | 120 | 500 | N/A | 813 | N/A | 290 | 550 | N/A | N/A | 50 |
| 300Te | 10279 | 300 | 340 | N/A | 205 | 465 | 305 | 150 | 254 | 130 | 600 | N/A | 958 | N/A | 305 | 600 | N/A | N/A | 50 |
| 400Te | 10280 | 400 | 560 | N/A | 230 | 560 | 350 | 175 | 254 | 165 | 680 | N/A | 1108 | N/A | 325 | 695 | N/A | N/A | 50 |
| 500Te | 10281 | 500 | 685 | N/A | 255 | 615 | 570 | 185 | 300 | 180 | 700 | N/A | 1158 | N/A | 350 | 750 | N/A | N/A | 55 |
| 600Te | 10282 | 600 | 880 | N/A | 285 | 675 | 405 | 205 | 300 | 195 | 700 | N/A | 1200 | N/A | 375 | 845 | N/A | N/A | 60 |
| 700Te | 10283 | 700 | 980 | N/A | 310 | 720 | 435 | 217 | 330 | 205 | 700 | N/A | 1231 | N/A | 400 | 890 | N/A | N/A | 60 |
| 800Te | 10284 | 800 | 1100 | N/A | 310 | 730 | 435 | 217 | 330 | 210 | 700 | N/A | 1236 | N/A | 400 | 900 | N/A | N/A | 60 |
| 900Te | 10285 | 900 | 1280 | N/A | 330 | 770 | 465 | 230 | 355 | 220 | 700 | N/A | 1268 | N/A | 420 | 944 | N/A | N/A | 60 |
| 1000Te | 10286 | 1000 | 1460 | N/A | 350 | 810 | 480 | 240 | 355 | 230 | 750 | N/A | 1290 | N/A | 420 | 953 | N/A | N/A | 60 |
(B) = Bow shackle
(D) = D shackle
Diagrams:
Wireless load shackle typical dimensions:
| Product codes | Load rating (tonnes) | Weight bow (kg) | Weight D (kg) | A mm | B mm | C mm | D mm | E mm | F mm | G mm (B) | G mm (D) | H mm (B) | H mm (D) | I mm (B) | J mm | K mm | L mm | M mm | |
| 8.5Te | 9660 | 8.5 | 2.6 | 2.5 | 43 | 93 | 59 | 28 | 44 | 25 | 95 | 85 | 164 | 154 | 68 | 224 | 200 | 100 | 119 |
| 12Te | 9661 | 12 | 4.9 | 4.5 | 51 | 115 | 72 | 35 | 50 | 32 | 115 | 94 | 201 | 180 | 83 | 274 | 200 | 100 | 119 |
| 17Te | 9662 | 17 | 8.2 | 7.6 | 60 | 136 | 88 | 42 | 63 | 38 | 146 | 127 | 249 | 230 | 99 | 304 | 200 | 100 | 119 |
| 25Te | 9663 | 25 | 14.2 | 12.9 | 74 | 164 | 103 | 50 | 88 | 45 | 178 | 149 | 300 | 271 | 126 | 338 | 200 | 100 | 119 |
| 35Te | 9664 | 35 | 19.9 | 17.4 | 83 | 183 | 111 | 57 | 88 | 50 | 197 | 171 | 331 | 305 | 138 | 361 | 200 | 100 | 121 |
| 55Te | 9665 | 55 | 39.6 | 35.3 | 105 | 235 | 145 | 70 | 114 | 65 | 260 | 203 | 433 | 376 | 180 | 410 | 210 | 110 | 118 |
| 85Te | 9666 | 85 | 62 | 53 | 127 | 273 | 162 | 83 | 125 | 75 | 329 | 339 | 527 | 427 | 190 | 454 | 220 | 120 | 118 |
| 120Te | 9667 | 120 | 110 | N/A | 150 | 328 | 200 | 95 | 152 | 89 | 380 | N/A | 617 | N/A | 238 | 482 | N/A | N/A | 92 |
| 150Te | 9668 | 150 | 160 | N/A | 170 | 374 | 230 | 108 | 165 | 102 | 400 | N/A | 671 | N/A | 275 | 535 | N/A | N/A | 92 |
| 200Te | 9669 | 200 | 235 | N/A | 180 | 420 | 260 | 140 | 190 | 120 | 500 | N/A | 813 | N/A | 290 | 615 | 176 | 80 | 115 |
| 300Te | 9670 | 300 | 340 | N/A | 205 | 465 | 305 | 150 | 254 | 130 | 600 | N/A | 958 | N/A | 305 | 665 | 203 | 100 | 115 |
| 400Te | 9671 | 400 | 560 | N/A | 230 | 560 | 350 | 175 | 254 | 165 | 680 | N/A | 1108 | N/A | 325 | 762 | N/A | N/A | 117 |
| 500Te | 9672 | 500 | 685 | N/A | 255 | 615 | 570 | 185 | 300 | 180 | 700 | N/A | 1158 | N/A | 350 | 817 | N/A | N/A | 122 |
| 600Te | 9965 | 600 | 880 | N/A | 285 | 675 | 405 | 205 | 300 | 195 | 700 | N/A | 1200 | N/A | 375 | 912 | N/A | N/A | 127 |
| 700Te | 9966 | 700 | 980 | N/A | 310 | 720 | 435 | 217 | 330 | 205 | 700 | N/A | 1231 | N/A | 400 | 957 | N/A | N/A | 127 |
| 800Te | 9967 | 800 | 1100 | N/A | 310 | 730 | 435 | 217 | 330 | 210 | 700 | N/A | 1236 | N/A | 400 | 967 | N/A | N/A | 127 |
| 900Te | 9968 | 900 | 1280 | N/A | 330 | 770 | 465 | 230 | 355 | 220 | 700 | N/A | 1268 | N/A | 420 | 1011 | N/A | N/A | 127 |
| 1000Te | 9969 | 1000 | 1460 | N/A | 350 | 810 | 480 | 240 | 355 | 230 | 750 | N/A | 1290 | N/A | 420 | 1020 | N/A | N/A | 127 |
(B) = Bow shackle
(D) = D shackle
Available options:
- Available with SmartLoad® technology
- Cabled or wireless
- Hazardous area Zone 1 and 2
- Subsea
- Bow or D type
Subsea load shackle:
Scotload’s subsea load shackles are available as a ‘D’ or ‘Bow’ shackle body with load centralising bobbins, plug and socket extensions, displays and signal conditioning units with a robust carry case.
Specially designed for use in underwater applications, our load shackles are supplied with subcon connectors and deep sea protection, so they are unaffected by the outside water pressure whilst remaining sensitive in the intended load measuring direction.